Yoshida, Hajime; Kosaku, Yasuo*; Enoeda, Mikio; Abe, Tetsuya; Akiba, Masato
JAERI-Research 2005-003, 13 Pages, 2005/03
Hydrogen permeation fluxes of the reduced activation ferritic steel F82H were quantitatively measured by a newly proposed method, vacuum thermo-balance method, for a precise estimation of tritium leakage in a fusion reactor. We prepared sample capsules made of F82H, which enclosed hydrogen gas. The hydrogen in the capsules permeated through the capsule wall, and subsequently desorbed from the capsule surface during isothermal heating. The vacuum thermo-balance method allows simultaneous measurement of the hydrogen permeation flux by two independent methods, namely, the net weight reduction of the sample capsule and exhaust gas analysis. Thus the simultaneous measurements by two independent methods increase the reliability of the permeability measurement. The ratio of the hydrogen permeation fluxes obtained by the net weight reduction to that measured by the exhaust gas analysis was in the range from 1/4 to 1/1 in this experiment. It has been demonstrated that the vacuum thermo-balance method is effective for the measurement of hydrogen permeation rate of F82H.
Terada, Yasuaki*; Ochiai, Kentaro; Sato, Satoshi; Wada, Masayuki*; Klix, A.; Yamauchi, Michinori*; Hori, Junichi; Nishitani, Takeo
JAERI-Research 2002-019, 70 Pages, 2002/10
D-T neutron irradiation experiments have been carried out with a F82H-containing breeding blanket mock-up of a fusion in order to investigate the activation characteristics of F82H low activation stainless steel. We have measured reaction rates producing 54Mn, 56Mn, 51Cr and 187W in foils of F82H, chromium and tungsten. MCNP calculations were done with evaluated nuclear data from the JENDL-3.2 and the FENDL/E-2.0 files and the results were compared with the measured values. The comparison shows that by using the current data files the reaction rates obtained from the calculations will be overestimated by up to 10-20% for 54Mn, 56Mn and 51Cr, up to 30-40% for 187W, respectively. The calculated values for tungsten are different with the evaluated nuclear data library, which shows that the neutron capture cross sections of tungsten have discrepancy in the resonance region for each nuclear data libraries.
; Mori, Masahiro; Kikuchi, Mitsuru; Ninomiya, Hiromasa; Jitsukawa, Shiro; Ito, Takao; Kuriyama, Masaaki;
16th IEEE/NPSS Symp. on Fusion Engineering (SOFE '95), p.1214 - 1217, 1995/06
no abstracts in English